1151E Ionisasion |
|
|
Description:
Optimised for fast, flaming fires 50μA max standby current 43mm higt in B401 base 102mm diameter in B401 base 102g weight conforms to EN54-7. |
Specifications:
50μΑ standby.
Top activation speed 6m / sec.
Height 43mm on a Β401 base.
Diameter 102 on a Β401 base.
Weight 102 gr.
Adaptable on en54-7.
|
Order |
|
|
|
|
|
|
|
4451E |
|
|
Description:
Fixed temperature alarm 78oC 100μA standby current Dual thermistor technology 53mm high in B401 base 102mm diameter in B401 base 150g weight Conforms to EN54-8. |
Specifications:
100μA standby.
Double Thermic Technology.
Height 53mm on a B401 Base.
Weight 150 gr.
|
Order |
|
|
|
|
|
|
|
B424RL Latching relay base |
|
|
Description:
For use in 12V and 24VDC systems, Normally open or closed contacts, Detector and relay latch into alarm, Accepts standard plug-in detectors, Remote LED connection. |
Specifications:
For use in 12V and 24VDC systems, Normally open or closed contacts, Detector and relay latch into alarm, Accepts standard plug-in detectors, Remote LED connection.
|
Order |
|
|
|
|
|
|
|
ADR-265 |
|
|
Description:
Particularly appropriate for protecting area from 10 – 100 meters. The system comprises of three parts:
The transmitter, the receiver and the circuit control system. The transmitter projects modulated infrared beams ( 880 nm ) sent to the receiver through reflectors. Reduction of infrared’s intensity in case of smoke, is detected from the circuit control system and from the loop is transmitted to the control panel. Four sensitivity settings within the alarms limit of 25%, 35%, 50%, 65% coverage per meter.
Loop activates both the circuit control system and the receiver which can also be powered to initiate its functions from other sources within the range of 17 Vdo – 28 Vdo. |
Specifications:
Type: addressable beam detector
Voltage: 17V – 28V
Standby current: 17mA
Led – aided alignment : red
Operating temperature range: -10C up to 55C
|
Order |
|
|
|
|
|
|
|
FP Range |
|
|
Description:
The FP Range of conventional fire alarm control panels is ideal for all types of commercial and residential property including schools, shops, factories house in multiple occupation etc. etc. |
Specifications:
Liff-off lid for easy first fix and straightforward maintanance, Available in 2, 4, 6, 8, 10, 12, and 14 zone versions, Open or short circuit fault indication on each zone, Detector and sounder circuits share common - Ve, allowing three wire retroinstall
|
Order |
|
|
|
|
|
|
|
ADR-910 |
|
|
Description:
It connected to the loop of an addreassable fire control panel. By breaking the glass it sends signals to the control panel and a fire condition is activated. Led - aided alignment is included and powered at the same time. |
Specifications:
Type: Brak glass call point
Voltage range: 17V - 28V
Standby current: 270Ma
Led - aided aligment: red
Operating temparture range: -20C up to 70C
Dimensions: 87 x 87 x 52 mm
|
Order |
|
|
|
|